From ampere to watt, from kW to horsepower or from watt to kWh: convert the key electrical units. For ampere–watt you enter the voltage (usually 230 V in Europe), and for energy the time in hours. That way you always get a correct, grounded answer instead of a rough rule of thumb.

Result

2,300 W

Power

Formula

P (W) = U (V) × I (A); E (kWh) = P (W) × t (h) ÷ 1000; 1 hp = 735.49875 W

Power (watt) is voltage (volt) times current (ampere), which is why ampere–watt conversion needs the voltage. Energy (kWh) is power times time: 1000 watts for 1 hour is 1 kWh. Metric horsepower is a fixed multiple: 1 hp = 735.49875 watts.

Step by step

  1. 1Choose what to convert (e.g. ampere → watt).
  2. 2Enter the value, plus voltage or time if asked.
  3. 3Read the result.

Worked examples

10 A at 230 V to watt

2,300 W (10 × 230).

100 kW to hp

≈ 135.96 hp.

Reference table

Ampere to watt at 230 V
Ampere (A)Watt (W)Example
1 A230 WSmall fan
4 A920 WToaster
10 A2,300 WKettle
16 A3,680 WStandard household circuit
25 A5,750 WHeavy appliance / EV charger

W = A × V. At 400 V (three-phase) the power is ~1.73× higher per phase.

kW to hp
kWhp / pk
50 kW68 hp
75 kW102 hp
100 kW136 hp
150 kW204 hp
200 kW272 hp

1 hp = 735.49875 W (metric horsepower).

Common mistakes

  • Converting ampere to watt without the voltage; it cannot be done without volts.
  • Confusing watt (power) and kWh (energy); energy needs time.
  • Mixing metric hp and US hp (small difference).

When to use it

  • Checking how many amps a 3,000 W appliance draws at 230 V.
  • Converting engine power from kW to hp in a car listing.
  • Estimating an appliance's energy use in kWh for your energy bill.

Frequently asked questions

How many watts is 1 ampere?

It depends on the voltage: W = A × V. At 230 V, 1 A equals 230 W.

How many hp is 100 kW?

About 135.96 hp (100,000 W ÷ 735.49875).

How do I convert watt to kWh?

Multiply the power in watts by the time in hours and divide by 1000. 2000 W × 3 h ÷ 1000 = 6 kWh.

Which voltage should I use?

For household use in Europe that is usually 230 V (single phase). For power circuits it is 400 V (three phase).